{"id":123,"date":"2026-09-03T20:45:48","date_gmt":"2026-09-03T20:45:48","guid":{"rendered":"https:\/\/labirue.pl\/webpage\/?p=123"},"modified":"2026-09-22T12:39:58","modified_gmt":"2026-09-22T10:39:58","slug":"reflections","status":"publish","type":"post","link":"https:\/\/labirue.pl\/webpage\/articles\/reflections\/","title":{"rendered":"Reflections"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Modern embedded systems may have multigigabit speed operated connections. In professional electronics development it is not enough to see if test sample is working.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Not allways full computer singal integrity simulations are possible or they are too optimistic like depicted below:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"344\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulation-1024x344.jpg\" alt=\"Eye diagram of SGMII link\" class=\"wp-image-486\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulation-1024x344.jpg 1024w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulation-300x101.jpg 300w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulation-768x258.jpg 768w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulation.jpg 1044w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Simulated eye diagram<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Sometimes there is lack of connector S-parameter models and complicated elektromechanical design and we have to perform phisical measurements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Probe placement point dilemma<\/h2>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"532\" height=\"488\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/placement.jpg\" alt=\"SGMII AC capacitor and IC, measurement probe placement\" class=\"wp-image-489 size-full\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/placement.jpg 532w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/placement-300x275.jpg 300w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Here we are tryng to measure 1.25GHz SERDES signal. Receiver is in QFN pacakge and line AC coupling series 100nF capacitors are in about 2 length of C0402 package from IC. 100R termination in built into IC. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is much easier to locate active HiZ differential probe there. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Our wavelength on typical PCB FR4 has 114mm when our probe location is at distance of about 2mm.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Eye diagram of SERDES captured @ AC coupling capacitors with IC present looks terribly.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"625\" height=\"528\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/reflections-e1789218486350.jpg\" alt=\"Signal integrity of SERDES with closed eye due to HF reflections\" class=\"wp-image-490 size-full\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/reflections-e1789218486350.jpg 625w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/reflections-e1789218486350-300x253.jpg 300w\" sizes=\"auto, (max-width: 625px) 100vw, 625px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Parasitic capacitance effects<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Below depicted how different parasitic capacitance to ground in receiver circuit affect measured signal shape. Capacitors connected at both ends of termination resistor located at QFN IC pins to grounded PAD under QFN IC used to simulate different conditions.<\/p>\n\n\n\n<div class=\"wp-block-group has-base-background-color has-background is-layout-grid wp-container-core-group-is-layout-35c9b63a wp-block-group-is-layout-grid\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"843\" height=\"684\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/termination.png\" alt=\"Serdes termination circuit simulation image\" class=\"wp-image-488\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/termination.png 843w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/termination-300x243.png 300w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/termination-768x623.png 768w\" sizes=\"auto, (max-width: 843px) 100vw, 843px\" \/><figcaption class=\"wp-element-caption\">RC termination equivalent<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full wp-container-content-a37929a5\"><img loading=\"lazy\" decoding=\"async\" width=\"518\" height=\"441\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/100R_terminated-e1789219304197.jpg\" alt=\"Properly opened eye of SERDES link\" class=\"wp-image-491\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/100R_terminated-e1789219304197.jpg 518w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/100R_terminated-e1789219304197-300x255.jpg 300w\" sizes=\"auto, (max-width: 518px) 100vw, 518px\" \/><figcaption class=\"wp-element-caption\">100R terminated<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"327\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/2p2_100R-1024x327.jpg\" alt=\"Acceptable parasitic capacitance loading termination port of SGMII SERDES. \" class=\"wp-image-492\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/2p2_100R-1024x327.jpg 1024w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/2p2_100R-300x96.jpg 300w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/2p2_100R-768x245.jpg 768w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/2p2_100R.jpg 1039w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">2p2 +100R + 2p2<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"910\" height=\"233\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/100R_6.8p.jpg\" alt=\"Non acceptable parasitic capacitance loading termination port of SGMII SERDES. \" class=\"wp-image-493\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/100R_6.8p.jpg 910w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/100R_6.8p-300x77.jpg 300w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/100R_6.8p-768x197.jpg 768w\" sizes=\"auto, (max-width: 910px) 100vw, 910px\" \/><figcaption class=\"wp-element-caption\">6p8 +100R + 6p8<\/figcaption><\/figure>\n<\/div>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-surface-background-color has-background wp-block-paragraph\">More parasitic pins capacitance, more front edge of waveform is attenuated by reflected wave.<\/p>\n<\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\">Proper approach<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There is need for forward channel simulation performed by oscilloscope called \u201cdeembedding\u201d.<br>To make it happen we need to have probe tip model or the best S-parameters and also IC packaging and receiver parasitic specification.<br>Here we are dealing with differential pair thus 4 port S-parameters are used.<br>Oscilloscope gets signal from differential probe thus 2-port S-parameters are needed.<br>Building this signal chain in software like Keysight ADS and creating transmission channel S21 parameters we can feed them into oscilloscope to enable channel deembedding.<\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Finally we see that signal received internally by IC does not look so bad.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"636\" height=\"615\" src=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulated.jpg\" alt=\"SGMII eye at IR receiver level after deembedding\" class=\"wp-image-496 size-full\" srcset=\"https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulated.jpg 636w, https:\/\/labirue.pl\/webpage\/wp-content\/uploads\/2026\/09\/simulated-300x290.jpg 300w\" sizes=\"auto, (max-width: 636px) 100vw, 636px\" \/><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">On the other hand first vendors provided simulation model does not considered internal parasites that resulted in almost perfect simulation results.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>It is not enough to have access to top measurement equipment. There is also need to understand how to properly configured it and make measurement.<\/p>\n","protected":false},"author":1,"featured_media":446,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"pgc_sgb_lightbox_settings":"","slim_seo":{"title":"Reflections - LABiRUE","description":"It is not enough to have access to top measurement equipment. There is also need to understand how to properly configured it and make measurement."},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":28,"footnotes":""},"categories":[27],"tags":[28,30,29],"class_list":["post-123","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-signalintegrity","tag-hifreq","tag-serdes","tag-si"],"_links":{"self":[{"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/posts\/123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/comments?post=123"}],"version-history":[{"count":14,"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/posts\/123\/revisions"}],"predecessor-version":[{"id":773,"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/posts\/123\/revisions\/773"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/media\/446"}],"wp:attachment":[{"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/media?parent=123"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/categories?post=123"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/labirue.pl\/webpage\/wp-json\/wp\/v2\/tags?post=123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}